Assure ID® Safety Pen Needles

Safe. Easy to use. Cost effective.

Assure ID Safety Pen Needles, from the brand you trust for safety and quality, offer features you require at a more cost-effective price than the market leaders.

Assure ID Safety Pen Needles are now available in three models: Assure ID DUO PRO (with back-end shield), Assure ID PRO (without back-end shield) and Assure ID Standard.

Features

Assure ID Safety Pen Needles are now available in three models

Size

Showing Assure ID Cartons of three different sizes for healthcare professionals and diabetes management with ARKRAY USA, Inc. Assure ID Safety Pen Needles.

Safety Before

Close-up of the safety cover before. ClearPrime™ safety cover allows view of priming drops to ensure safe operation and delivery. Clear shield covers needle before injection to prevent needle exposure. Assure ID. Healthcare professionals and diabetes management. ARKRAY USA, Inc.
  • ClearPrime™ safety cover allows view of priming drops to ensure safe operation and delivery.
  • Clear shield covers needle before injection to prevent needle exposure.

Safety After

Safety after. Front-end safety shield to help protect against accidental needle sticks. Red indicator to signal the safety shield has activated. Back-end safety shield to help protect against accidental needle sticks. (Assure ID DUO PRO Safety Pen Needle) Easy viewing safety cover. Healthcare professionals and diabetes management. ARKRAY USA, Inc.
  • Front-end safety shield to help protect against accidental needle sticks.
  • Red indicator to signal the safety shield has activated.
  • Back-end safety shield to help protect against accidental needle sticks. (Assure ID DUO PRO Safety Pen Needle)
  • Easy viewing safety cover.

Comfort

  • Needle lubrication designed to support smooth injections.
  • Tri-bevel needle for comfortable injections.

Universal Fit

Assure ID PRO pen. Fits securely to major pen devices from leading manufacturers, including: Sanofi Aventis: ClikSTAR®, SoloSTAR®, JuniorSTAR® Lilly: KwikPen®, HumaPen® Memoir, HumaPen® Luxura HD, HumaPen® Luxura, HumaPen® Savvio, HumaPen® Ergo II, Humalog® Pen. Novo Nordisk: FlexTouch®, NovoPen® 3, 4 and 5, InnoLet®, FlexPen®, Victoza®, NovoPen® Echo. Owen Mumford: Autopen® Classic, Autopen® Junior. Berlin Chemie: BerliPen® Areo, BerliPen® Junior. Healthcare professionals and diabetes management. ARKRAY USA, Inc.
  • Fits securely to major pen devices from leading manufacturers, including:
  • Sanofi Aventis: ClikSTAR®, SoloSTAR®, JuniorSTAR®
  • Lilly: KwikPen®, HumaPen® Memoir, HumaPen® Luxura HD, HumaPen® Luxura, HumaPen® Savvio, HumaPen® Ergo II, Humalog® Pen
  • Novo Nordisk: FlexTouch®, NovoPen® 3, 4 and 5, InnoLet®, FlexPen®, Victoza®, NovoPen® Echo
  • Owen Mumford: Autopen® Classic, Autopen® Junior
  • Berlin Chemie: BerliPen® Areo, BerliPen® Junior

On-site and online training

ARKRAY goes beyond products to support your facility’s safety goals. This includes in-person, in-service training, guides, and video training for all shifts. It’s an important tool for your team to gain confidence in their ability to meet the needs of your residents.

Instructions for Use: Assure ID DUO PRO and PRO Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.

Play Video

Assure ID DUO PRO/PRO Safety Pen Needle Training Guide Video

Attaching the needle to the pen injection device

Closeup icon of Step 1 - fingers removing the safety seal for the Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 1

Remove the seal from the safety pen needle.

For your safety

  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime™ safety cover from the safety pen needle until instructed to do so.
Closeup Icon of the tip of the pen for Step 2 - Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 2

Attach the safety pen needle securely to the pen injector device by twisting clockwise until it stops. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.

For your safety

  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Closeup Icon of pen and fingers for for Step 3 for the Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 3

Prime the pen injector device according to the pen injector device instructions for use.

For your safety

  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient’s side.

Performing the injection

Close Up Icon of fingers and pen to represent Step 4: When ready to inject, remove the safety cover from the safety pen needle to expose the needle. Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 4

When ready to inject, remove the safety cover from the safety pen needle to expose the needle.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Icon of fingers, pen and skin to represent Step 5: Inject into the skin as recommended by your physician with or without a skin liftAssure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 5

Inject into the skin as recommended by your physician with or without a skin lift.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Icon of stop watch and thumb on pen to represent Step 6: Hold the injection for 5 to 10 seconds before withdrawal as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication. Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 6

Hold the injection for 5 to 10 seconds before withdrawal as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.

Icon of an arrow pointing up and with pen being held downwards to represent Step 7: Remove the safety pen needle by lifting straight-up from the injection site. The patient-end safety mechanism is activated automatically when needle is withdrawn from the skin. Assure ID DUO PRO and-PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 7

Remove the safety pen needle by lifting straight-up from the injection site. The patient-end safety mechanism is activated automatically when needle is withdrawn from the skin.

For your safety

  • Do not remove the needle at an angle.
  • The automatic patient-end safety shield will engage and cover the needle when you lift the pen injection device from the patient’s skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.
Icon of arrow pointing to the right placing the cap on the pen to represent Step 8: Attach the cover securely by pushing cover over the patient-end safety shield. Assure ID DUO PRO and PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 8

Attach the cover securely by pushing cover over the patient-end safety shield.

For your safety

  • Do not grasp or twist on the patient-end safety shield or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.
Icon with arrow "moving" in a circle to represent Step 9: Remove the safety pen needle from the pen injector device by twisting counter-clockwise. Assure ID DUO PRO and PRO Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 9

Remove the safety pen needle from the pen injector device by twisting counter-clockwise. The pen connection-end safety shield will automatically engage when removed to assist in needlestick prevention. Dispose of in a sharps container. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.

For your safety

  • The pen connection-end safety shield will automatically engage when the needle is removed from the pen injector device (DUO PRO only).
  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Instructions for Use: Assure ID Standard Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.
Play Video

Assure ID Standard Safety Pen Needle Training Guide Video

Attaching the needle to the pen injection device

Icon of arrow to represent Step 1 - Remove the seal from the safety pen needle by peeling back carefully and discard. Assure ID® Safety Pen Needles with ARKRAY USA, Inc.

Step 1

Remove the seal from the safety pen needle by peeling back carefully and discard.

For your safety

  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime™ safety cover from the safety pen needle until instructed to do so.
Icon of arrow and pen cap to represent Step 2 - Attach the safety pen needle securely to the pen injection device by twisting (as shown) clockwise until it is attached securely. Assure ID Safety Pen Needles Instructions with ARKRAY USA, Inc.

Step 2

Attach the safety pen needle securely to the pen injection device by twisting (as shown) clockwise until it is attached securely.

For your safety

  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Icon of pen and arrow to represent Step 3 - Assure ID Safety Pen Needles Instructions. Prime the pen injector device according to the pen injector device instructions for use. ARKRAY USA, Inc.

Step 3

Prime the pen injection device according to the instructions for the pen injection device. Note: you can see the priming drops through the ClearPrime™ safety cover.

For your safety

  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient’s side.

Performing the injection

Icon of pen and arrow to represent Step 4 - When you are by the patient and ready to inject, remove the ClearPrime™ safety cover from the safety pen needle to expose the needle. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 4

When you are by the patient and ready to inject, remove the ClearPrime™ safety cover from the safety pen needle to expose the needle.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Icon of pen needle and skin to represent Step 5 - Inject into the skin as recommended by your physician with or without a skin lift. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 5

Inject into the skin as recommended by your physician with or without a skin lift.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Icon of stopwatch to represent Step 6 - Hold the injection for 5 to 10 seconds before withdrawal as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 6

Hold the injection for 5 to 10 seconds before withdrawing from the injection site as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.

Icon of pen needle with an "up" arrow to represent Step 7 - Remove the needle from the injection site by lifting straight up from the injection site. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 7

Remove the needle from the injection site by lifting straight up from the injection site.

For your safety

  • Do not remove the needle at an angle.
  • The automatic safety shield will engage and cover the shielded needle when you lift the pen injection device from the patient’s skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.
Icon of pen tip and arrow pointing "right" to represent Step 8 - Attach the cover securely by pushing cover over the patient-end safety shield. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 8

Attach the clear cover securely over the shielded needle by pushing the cover over the shielded needle and white barrel.

For your safety

  • Do not grasp or twist on the colored safety shield (turquoise-8mm) or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.
Icon of pen/needle cap to represent Step 9 - Remove the safety pen needle from the pen injection device by twisting counter-clockwise with your fingers on the clear cover. Assure ID Safety Pen Needles Instructions. ARKRAY USA, Inc.

Step 9

Remove the safety pen needle from the pen injection device by twisting counter-clockwise with your fingers on the clear cover. Immediately dispose of used safety pen needle in an approved sharps container and according to your sharps safety protocol.

For your safety

  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Ordering Information

Assure ID DUO PRO and PRO Safety Pen Needle for healthcare professionals and diabetes management with ARKRAY USA, Inc.

Assure ID DUO PRO and PRO Safety Pen Needle

Assure ID DUO PRO Safety Pen Needle

Column 1Column 2
Gauge31
Length (inch|mm)3/16"|5mm
Qty100
Case Qty.1200
Product #277531
UPC 015482277536
Reimb. 083172775-31

Assure ID PRO Safety Pen Needle

Column 1Column 2
Gauge30
Length (inch|mm)3/16"|5mm
Qty100
Case Qty.1200
Product #276530
UPC 015482276539
Reimb. 083172765-30
Assure ID Standard Safety Pen Needle for healthcare professionals for diabetes management for their patients with ARKRAY USA, Inc.

Assure ID Standard Safety Pen Needle

Assure ID Standard Safety Pen Needle

Column 1Column 2
Gauge30
Length (inch|mm)5/16"|8mm
Qty100
Case Qty.1200
Product #278130
UPC 015482278304
Reimb. 083172781-30

Information Request / Pen Needle Evaluation

If you would like to do an evaluation of the Assure ID Safety Pen Needles, please complete the form and an ARKRAY rep will follow-up with you quickly.

Assure ID Safety Pen Needles for Healthcare Professionals. ARKRAY USA, Inc.